MRI Compact
1.5T MRI in one free-standing pod, based on mobile MRI trailer layouts.
Floor plan to followThis pod is being redrawn on the 12' × 32' RESPAND grid. Room areas follow with the plan.
Planned as 1 pod + 1 optional support pod. Pod count and floor area are confirmed when the plan is redrawn on the grid.
What it adds
- One pod, end to end: magnet room with RF cage, then control room, then equipment area
- Based on mobile MRI trailer layouts (approx. 48 ft × 8.5 ft inside). The pod is shorter (39 ft) and wider (11 ft)
- Optional support pod: patient change, reception, waiting and washroom
- Free-standing: the 5-gauss line can extend outside the pod
Building systems
- RF shielding
- Quench vent
- Chiller
- Dedicated power
- Reinforced floor
Rooms
| Magnet Room | — |
| Control | — |
| Equipment | — |
| Optional support pod: Patient Change | — |
| Optional support pod: Washroom | — |
| Optional support pod: Reception & Waiting | — |
Furniture & equipment
- • Compact or short-bore 1.5T MRI (model confirmed after the fit check)
- • Patient table
- • RF cage with RF-shielded door and viewing window
- • Quench vent pipe to the exterior
- • MRI control console and workstation
- • Operator chair
- • Gradient and RF cabinets
- • Chiller
- • Power distribution unit
- • Support pod: reception counter, waiting chairs, change cubicles and lockers, accessible washroom
Preliminary. Confirm with vendor site-planning guide.
Fit check
| Pods required | 1 pod + 1 optional support pod |
|---|---|
| Floor area | Confirmed with the plan on the 12' × 32' grid |
| Point load | Magnet, approx. 4,000–5,000 kg |
| Power | Dedicated supply; chiller |
| Shielding | RF cage; 5-gauss zone outside the pod |
Preliminary. Confirm with vendor site-planning guide.
Equipment values
UnitPreliminary
Compact or short-bore 1.5T MRI. No model is named until the fit is confirmed
Layout basisPreliminary
Mobile MRI trailer layouts, approx. 48 ft × 8.5 ft inside
Magnet weightPreliminary
approx. 4,000 to 5,000 kg (typical 1.5T), taken as a concentrated load
Every value above: Preliminary. Confirm with vendor site-planning guide.
Design notes
- Limited patient comfort and throughput compared with the MRI Suite
- The 5-gauss line can extend outside the pod: control the exterior zone (fencing and signs)
- If the support pod joins the MRI pod, keep reception and waiting at the end away from the magnet, and confirm with the vendor's field plot
- Quench vent to the exterior
- Chiller and dedicated power
- Trailer layouts are approx. 48 ft long and the pod is 39 ft long inside: confirm the magnet room length with the vendor
Optional support pod (RP-MRC-S) · 1 pod
Optional: patient change, reception, waiting and washroom for the MRI Compact. Add it with the MRI pod in the configurator.
- Patient Change
- Washroom
- Reception & Waiting
Add MRI Compact to your clinic
Configure in 3D and reserve your engineering and production slot.